The G4630 is more than a power quality analyser. With trigger-free continuous waveform recording, it captures the complete picture of your electrical network. As renewables, BESS, data centers, UPS systems, drives, and other power-electronic loads transform electrical networks, power quality issues are becoming more complex. The G4630 continuously captures and records even the short, intermittent, and oscillatory events so you can predict, prevent and troubleshoot easily and with confidence.
Elspec G4630
Description
Elspec G4630 Power Quality and Grid Stability Analyser
The Full Electrical Story – Not Only the Events You Predicted
The G4630 is more than a power quality analyser. With trigger-free continuous waveform recording, it captures the complete picture of your electrical network. As renewables, BESS, data centers, UPS systems, drives, and other power-electronic loads transform electrical networks, power quality issues are becoming more complex. The G4630 continuously captures and records even the short, intermittent, and oscillatory events so you can predict, prevent and troubleshoot easily and with confidence.
Continuous waveform recording
- The full waveform is recorded and stored without gaps
- Over 5000 power parameters
- @1/2 cycle resolution
- PQZIP compression
Advanced oscillation detection
- Detects, classifies and quantifies oscillatory behavior from inverter-based systems.
IEC 61000-4-30 Class A
- Certified for the highest accuracy class for power quality measurement.
IEC 61850 / PMU / DNP3 / Modbus
- A measurement node built for substation
- SCADA and grid automation networks
-
Synchronized Monitoring
- Aligns logged data from multiple units on a single time scale
- Any grid event can be traced precisely to its source.
One Platform. Multiple Power-System Roles
- Power Quality Monitoring
- Digital Fault Recording
- Synchrophasor / PMU
- Sequence-of-Events Recording
- Dynamic System Monitoring
- Energy & Billing Measurement
PQZIP Continuous Waveform Recording
The G4600 redefines what a power quality analyzer can do. Powered by PQZIP technology, it enables long-term, high-resolution waveform recording and storage without relying on preconfigured triggers. Engineers can investigate not only the event that crossed a threshold, but also the conditions leading up to it, the system’s recovery behavior, and related disturbances across the network for a more complete understanding of power quality performance.
- Threshold-free setup so there is to need for predefined the setup
- High-resolution waveform supports up to 1024 samples/cycle
- Synchronized measurement engine for simultaneous multi-channel sampling
- Up to the 511th Harmonic for wide-band Harmonics spectral visibility
- Precise ½ cycle frequency recording for fast frequency excursions, recovery behavior, generator start ups, UPS transitions, BESS response and grid-stability
Power quality analyzer with continuous waveform recording illustration to Detect, Quantify and Preserve The Evidence
Oscillation Detection for IBR-Dominant Systems
As renewable generation, BESS, UPS systems, power-electronic loads, FACTS/HVDC assets and weak-grid conditions increase, engineers need more than sag/swell logs. They need a power quality analyzer that can detect oscillatory behavior, quantify it, and connect it to the underlying waveform evidence.
Oscillation detection in Elspec’s G4600 power quality analyzer
- Detection range
- 0.05–55Hz oscillation detection for low-frequency and subsynchronous phenomena
- Severity states
- Real-time Event / Alarm / Trip classification with a clear severity hierarchy
- System integration
- Oscillation state and metrics available through supported protocols and PQZ data workflows
- Selectable parameters
- Operates on half-cycle or one-cycle parameters – frequency, RMS voltage/current, sequence components and power
- Calculated metrics
- Oscillation frequency, damping ratio, phase, maximum amplitude and average amplitude
- Operational response
- Use oscillation state to support alarms, digital outputs, relay outputs and Sapphire investigation.
Why it matters
Oscillations may stay within normal voltage or current limits while still indicating control-loop interaction, resonance, insufficient damping or developing instability. Continuous waveform recording gives engineers the evidence to validate models, replay behavior and perform deeper EMT or power-system studies after the event.
Communication, I/O & Cyber Security – Connectivity & Communications
A measurement node within the digital electrical infrastructure, not just a standalone power quality analyzer. Supports standard utility and industrial protocols for SCADA, protection, automation, and power quality systems. Efficient low-bandwidth communication enables reliable data transfer from remote sites, while seamless integration ensures secure and time-synchronized data exchange across modern networks.
Continuous waveform recording
- The full waveform recorded and stored without gaps
- Over 5000 power parameters
- @1/2 cycle resolution
- PQZIP compression.
Advanced oscillation detection
- Detects, classifies and quantifies oscillatory behavior from inverter-based systems.
IEC 61850 / PMU / DNP3 / Modbus
- A measurement node built for substation
- SCADA and grid automation networks.
Synchronized Monitoring
- Aligns logged data from multiple units on a single time scale, so any grid event can be traced precisely to its source.
Multi I/O Modules
- 24 Digital inputs
- 12 Digital outputs
- 12 Analog inputs
- 12 Analog outputs
- 9 Relay outputs
Where the G4600 Delivers
As renewable generation, BESS, UPS systems, power-electronic loads, FACTS/HVDC assets and weak-grid conditions increase, engineers need more than sag/swell logs. They need to detect oscillatory behavior, quantify it, and connect it to the underlying waveform evidence.
- Power Quality Monitoring for Data Centers & Critical Loads
- Data Centers & Critical Loads
- Captures UPS transfers & generator starts
- Switching events with full waveform context
- Protects uptime through pre-event visibility
- Utilities & Substations monitoring solutions
- Utilities & Substations
- IEC 61850 integration & PMU streaming
- Disturbance investigation from a single device
- Oscillation events time stamped with GPS/PTP accuracy
- Inverter-Based Generation & BESS monitoring solutions
- Inverter-Based Generation & BESS
- Inverter switching behavior and control-loop interaction
- Weak-grid dynamics
- Grid-code compliance recorded automatically
- Improving Industrial Plants power
- Industrial Plants
- Investigate production disruptions after the fact
- No trigger threshold needed
- Motor-drive harmonics, resonance andintermittent faults preserved
- R&D and Testing computer labs power quality solutions
- R&D and Testing
- Continuous high-resolution
- Electrical behavior capture
- Model validation & comparison
- Advanced analysis workflows
G4600 power quality analyzer features
Local & Central Interfaces
- G4600 power quality analyzer smart display
- A rugged 7″ touchscreen that automatically discovers one or multiple G4600 devices – RMS, power, energy, harmonics, phasors, waveforms, events and I/O status on site.
- Powered and connected over a single PoE cable. Multitouch, operable with work gloves, indoor or outdoor. Also handles meter configuration and firmware updates.
Elspec PQ SCADA Monitoring Software
- Real-time – live visibility
- RMS, power, harmonics, unbalance, flicker, phasors, waveform, energy and I/O views.
- Events – investigation
- PQ, system, custom, aggregated and I/O events with threshold, rate-of-change and T-time comparison, logic aggregation, duration, phase, severity and value
Reports – export anywhere
- EN50160, IEEE1159, grid-line-code reports, COMTRADE, PQDIF, PQZIP, Excel, CSV, PDF and image exports
- Fleet – multi-site analysis
- Centralized engineering software across many meters, sites and applications.
Technical Specification
Specifications
Voltage, current & frequency |
|||
Parameter |
Measurement range |
Resolution |
Accuracy |
|---|---|---|---|
| VRMS (AC/DC) | 0-1,000V¹ | 10mV | ±0.1% of nominal voltage |
| ARMS | 0.01-79A | 10mA | ±0.1% of nominal current |
| Voltage peak | up to 8kV | 10mV | ±0.1% of reading |
| Frequency (50Hz nom.) | 40-70Hz | 1mHz | ±1mHz |
| Frequency (60Hz nom.) | 40-70Hz | 1mHz | ±1mHz |
| ¹ with a footnote that accuracy applies from 5V. ±0.1% of nominal voltage accuracy for nominal voltage 110 to 690V. | |||
Harmonics, flicker & unbalance |
|||
Parameter |
Measurement range |
Resolution |
Accuracy |
| Harmonic order | 1 to 511 (subgroups per IEC 61000-4-7) | 0.01V | IEC 61000-4-7 |
| Inter-harmonic order | 1 to 511 (subgroups per IEC 61000-4-7) | 0.01V | IEC 61000-4-7 |
| THD (n = 50) | 0-1000% | 0.01% | ±0.25% |
| Phase angle | -180° to +180° | 0.01° | ±0.01° |
| Flicker (Pst, Plt) | 0-20 | 0.01 | ±5% |
| Flicker (Pst inst.) | 0-20 | 0.01 | ±8% |
| Voltage unbalance (neg./zero seq.) | 0-100% | 0.1% | 0.15% |
| Current unbalance (neg./zero seq.) | 0-100% | 0.1% | 0.5% |
Power & energy |
|||
Parameter |
Measurement range |
Resolution |
Accuracy |
| Active power | ±5kW × CT × PT ratio | 10mW | ±0.2% |
| Reactive power | ±5kVAr × CT × PT ratio | 10mVAr | ±0.5% |
| Apparent power | ±5kVA × CT × PT ratio | 10mVA | ±0.2% |
| Active energy | ±5kWh × CT × PT ratio | 10mWh | ±0.1% |
| Reactive energy | ±5kVArh × CT × PT ratio | 10mVArh | ±0.5% |
| Apparent energy | ±5kVAh × CT × PT ratio | 10mVAh | ±0.2% |
Inputs & sampling |
|||
Parameter |
G4610 |
G4620 |
G4630 |
| Voltage channels | AC/DC: 4 | AC/DC: 4 | AC/DC: 4 |
| Voltage range (direct) | 1,000 VAC/VDC | 1,000 VAC/VDC | 1,000 VAC/VDC |
| Input impedance / capacitance | 600V CAT IV / 1000V CAT III | 600V CAT IV / 1000V CAT III | 600V CAT IV / 1000V CAT III |
| Current channels | 4 | 4 | 4 |
| Current range | 0.01-79A | 0.01-79A | 0.01-79A |
| Current burden | 0.008VA @5A | 0.008VA @5A | 0.008VA @5A |
| Bandwidth | 6.25kHz | 12.5kHz | 25kHz |
| Sampling rate | 256 samples/cycle | 512 samples/cycle | 1024 samples/cycle |
| A/D converter | 24-bit | 24-bit | 24-bit |
| Harmonics reach (50Hz) | up to H128 | up to H256 | up to H511 |
PQZIP recording |
|||
Parameter |
G4610 |
G4620 |
G4630 |
| Continuous waveform | ~1 week | ~1 month | ~1 year |
| Method | Gap-less continuous recording of all electrical parameters – no event thresholds required | Gap-less continuous recording of all electrical parameters – no event thresholds required | Gap-less continuous recording of all electrical parameters – no event thresholds required |
| Event log memory | up to 100000 event logs | up to 100000 event logs | up to 100000 event logs |
| Internal memory | 64GB | 64GB | 64GB |
Communication, time sync & power |
|||
Parameter |
Specifications |
||
| Ethernet | 2 × RJ45, 10/100/1000Mbit | ||
| LAN protocols | Modbus TCP, DNP3, SSH, FTP, SFTP, PMU (IEEE C37.118), IEC 61850 (MMS/GOOSE/SV), PTP | ||
| Serial | RS-485 / 422, Modbus RTU, up to 115,200 baud, full duplex | ||
| Power over Ethernet | PoE-PSE output – 13W, 48VDC | ||
| Time synchronization | GPS / NTP / IRIG-B / PTP / PPS / Self | ||
| Sync accuracy | 0.5µs GPS & IRIG-B · 1µs PTP (Layer 2) · 100µs SNTP | ||
| Real-time clock | ±5ppm | ||
| Power supply | 85-264VAC, 47-63Hz · 120-370VDC · aux. 24VDC±20% | ||
| Low-voltage ride-through | up to 30 seconds | ||
Physical & environmental |
|||
Parameter |
Specifications |
||
| Dimensions | 174.6 × 231.7 × 183.2 mm (6.87″ × 9.12″ × 7.21″) | ||
| Weight | 1.66 kg base (3.66 lb)/ 2.03 kg (1 MIO) (4.48 lb) / 2.38 kg (2 MIO) (5.25 lb) | ||
| Mounting | DIN rail, enclosure or flat-surface | ||
| Ingress protection | IP 20 per IEC 60529 | ||
| Operating / storage temp | -20 to +70°C / -40 to +85°C | ||
| Humidity / altitude | 85% / up to 2,000m | ||
| Multi-I/O expansion | up to 3 modules: 24 DI, 12 DO, 12 AI, 12 AO, 9 relays | ||
Standard compliance |
|||
| Standards | IEC 61000-4-30 Class A, IEC 61000-4-7, IEC 61000-4-15, IEC 61000-4-19, IEEE 519, IEEE 1159, IEEE C37.118, IEC 62053-22/23/24, IEC 61850, EN 50160, IEC 62052-11/31, IEC 60068-2-1/2/6/14/27/57/78, IEC 60255-21-1/2/3, IEC 62262, IEC 60068-2-31, IEC 61010-1 safety, CISPR 32/FCC/ICES EMC, IEC 62586-1/2 | ||